Diagnostics 7156 Owner’s Guide
October 199546
Setting Data Error and Data Buffer Options
This function allows you to select the handling of data reception errors and to
select the size of the data buffer.
Caution: The DIP switches are set at the factory to predetermined settings and
should generally not be changed. If you must change the settings do so carefully
to avoid changing other functions. Run the print test to see what the current
settings for these options are. See “Print Test” later in this chapter.
1. Open the front cover and note what the current DIP switch settings are.
2. Set the DIP switches to the settings in the table you want for data reception
errors and the data buffer.
Switch 7 is always Off. Switch 8: On = knife, Off = non-knife
Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Option
On Off On Off Off Off Print “?” for Data
Errors (Default)
On Off On Off Off On Ignore Data Errors
On Off On Off On Off Set Data Buffer =
4K Bytes (Default)
On Off On Off On On Set Data Buffer =
One Line
Choose one of the Data Errors options and one of the Data Buffer options.
Other possible settings are not used.
3. Close the front cover and press the On Line button.
The green LED flashes when the printer cycles.
4. Set the DIP switches back to the settings for normal operation (on-line mode).
See “Switch Settings” in the “Communication” chapter for the settings.
5. Close the front cover and press the On Line button.
The green LED flashes when the printer cycles.
Ignoring/Using the Carriage Return
This function allows the printer to ignore or use the Carriage Return (Hex 0D)
command depending on the application. Some applications expect the command
to be ignored while others use the command as a print command.