Commands 7156 Owner’s Guide
October 1995114
3 = Transmit Error Status
Bit Status Hex Decimal Function
0 Off 00 0 Fixed to Off
1 On 02 2 Fixed to On
2 Off
On
00
04
0
4
No slip motor jam
Slip motor jam occured
3 Off
On
00
08
0
8
No knife error
Knife error occurred
4 On 10 16 Fixed to On
5 Off
On
00
20
0
32
No unrecoverable error
Unrecoverable error occurred
6 Off
On
00
40
0
64
Thermal printhead temp./power supply
voltage are in range
Thermal printhead temp./power supply
voltage are out of range
7 Off 00 0 Fixed to Off